Railway electrification provides faster and more reliable train journeys when compared to diesel trains, as well as a strong reduction of pollution in busy stations and the countryside. However, many national programmes for the electrification of new and existing railway lines have required a substantial investment in the railway infrastructure. One of the reasons is because railway electrification uses AC single-phase power that requires a connection to high-voltage transmission lines, which are not always available in the intended locations of railway feeder stations and, usually, require complicated and extremely expensive modifications of the existing layouts, e.g. tap and looped connections of the substations.
Additionally, new electric railways introduce intermittent load peaks that might affect the stability of the grid, especially for future scenarios where the inertia of the power system will be substantially reduced for the widespread adoption of renewable power sources. To facilitate the integration of renewable sources and increase the efficiency of the power distribution, there is currently a significant interest in medium voltage DC power distribution grids. The Flexible Medium Voltage DC Electric Railway Systems (MVDC-ERS) project investigates how medium voltage DC technology can be applied to railway electrification systems.
Overall concept
The typical power level of heavy railways, and even high-speed railways, are in the range of 100- 500 MVA, with individual supply points designed for a peak power of 50-100 MVA, which is compatible with the typical capabilities of medium-voltage distribution systems. However, for AC railways, the connection of railway feeder stations to the power distribution network would be possible only by adopting schemes that introduce only a very limited imbalance.
Traditional low voltage DC power supplies satisfy this requirement, as the DC voltage is generated by a three-phase diode rectifier that draws balanced current with high power factor. However, the maximum level of the DC voltage is 3kV for the limitation on the maximum short-circuit breaking current of DC circuit breakers. This, in turn, limits the maximum power of each traction power substation (TPS) to a few megawatts (MW) and the maximum distance between substations to a few kilometres (km). Additionally, a higher voltage of the DC power supply would pose problems for the traction system of the trains, which operates at voltage levels of a few kilovolts (kV). Moreover, the traditional concept of DC railways does not fit very well with the future vision of electric railways, which are better integrated with the power distribution networks, as the diode rectifiers are unidirectional and the power factor depends on the load inductance, and this prevents any control of the power flows and the power quality.
To address these challenges, MVDC-ERS proposes a new Medium Voltage DC (MVDC) traction power supply based on controlled bidirectional converters. In this system, medium‑voltage multilevel converters are used in the TPSs to connect the MVDC railway to the power distribution grid. These converters are based on individual building blocks (submodules), operating at around 3.3-6.5kV, that can be stacked in series to reach the desired level for the DC voltage. The converters can regulate the DC side voltage at the nominal value within a broad load range and limit the current during DC short circuit events. This means that the MVDC system can be implemented with DC circuit breakers designed for the nominal current or a value slightly higher than that, which are simpler and cheaper than high‑current MVDC circuit breakers.
With reference to the on-board traction systems, the main challenge of MVDC electrification is to find suitable alternatives to transformers to step-down the voltage to levels compatible with traction inverters and motors. To address this challenge, DC PETTs can be used to replace the traditional low frequency transformers. DC PETTs are medium-voltage DC-DC converters which utilise medium‑frequency transformers and, hence, achieve a higher power-density and efficiency.
The converters used in both TPSs and trains for MVDC electrification systems will also benefit significantly from the introduction of wide band‑gap semiconductor devices, like silicon carbide and gallium nitride, as the higher blocking voltages will lead to simpler topologies, and the higher switching frequencies will lead to higher power densities and higher energy efficiency.
The possibility of controlling the power flow between the power distribution and the electrification networks opens new scenarios for the interaction with the grid. In fact, the railway can be mesh fed, reducing the peak power of individual TPSs, without the risk of power circulation in parallel to the grid. An example is provided in Figure 1, indicating a section of the railway supplied by two feeder stations with in-situ renewable power sources. Depending on the traffic conditions, the railway can be operated to mitigate heavy traction loads using renewable sources, to reduce the power from the grid when there are light loads on the railway, to maximise the recuperation of regenerative braking and to support distant nodes of the power distribution network using the electrification line as a parallel path, mitigating constraints on the grid.